Before starting work on the reinforcement of columns, create new columns reinforcement styles.
In order to create a new reinforcement style:
Manage styles – Reinforcement –
Reinforcement style.
.|
Cover of top face |
25 |
|
Cover of side faces |
32 |
|
Cover of bottom face |
25 |
|
Reinforcement method |
Parametric welded |
|
Structure |
All objects |
|
Rebar |
ø20 A400 |
|
Number of width side rebars |
2 |
|
Number of depth side rebars |
2 |
|
Top overhang |
0 |
|
Rebar |
ø8 B500C |
|
Bar spacing |
300 |
|
Reinforcing zone length |
0 |
|
Top and bottom rebar dimensions |
100 |
button .Then reinforce the columns:
On the Primary panel select View settings
– Visual style – Wireframe to view the reinforcement of columns.
Reinforce the B-5 beams as follows:
– Visual style – Monochrome.
button in the appeared window.|
Cover |
40 |
|
Reinforcement method |
Parametric welded |
|
Structure |
All objects |
|
End Overhang length |
15 |
|
Rebar |
ø20 A400 |
|
Longitudinal rebar location |
60 |
|
Number of rebars |
3 |
|
Rebar |
ø20 A400 |
|
Number of rebars |
2 |
|
Rebar |
ø8 B500C |
|
Bar spacing |
300 |
|
Reinforcing zone length |
600 |
|
Top and bottom rebar dimensions |
100 |
Create and assign the new Reinforcement without strengthening style to B-1, B-2 and B-7 beams by any known method. All parameters of Reinforcement style does not differ from that described above, except for Reinforcing zone length parameter from transverse reinforcement of cage group. Change its value to 0.
To see how the reinforced objects looks select the Wireframe visual style.
Create and assign the Reinforcement B-6 and B-9 reinforcement style for B-3, B-6 and B-9 beams.
|
Cover |
48 |
|
Reinforcement method |
Parametric welded |
|
Structure |
All objects |
|
End Overhang length |
15 |
|
Overhangs |
At the begginning |
|
Hooks |
At the begginning |
|
Rebar |
ø16 A400 |
|
Longitudinal rebar location |
30 |
|
Number of rebars |
3 |
|
Overhang at the beginning |
250 |
|
Rebar |
ø20 A400 |
|
Number of rebars |
3 |
|
Overhang at the beginning |
370 |
|
Hook at the beginning |
100 |
|
Rebar style |
ø8 B500C |
|
Bar spacing |
300 |
|
Reinforcing zone length |
600 |
|
Top and bottom rebar dimensions |
100 |
Create and assign the Reinforcement B-8 and B-11 reinforcement style for B-8 and B-11 beams.
|
Cover |
20 |
|
Reinforcement method |
Parametric welded |
|
Structure |
All objects |
|
End Overhang length |
15 |
|
Overhangs |
At the begginning |
|
Hooks |
At the begginning |
|
Rebar |
ø16 A400 |
|
Longitudinal rebar location |
50 |
|
Number of rebars |
3 |
|
Overhang at the beginning |
280 |
|
Rebar |
ø20 A400 |
|
Number of rebars |
3 |
|
Overhang at the beginning |
370 |
|
Hook at the beginning |
250 |
|
Rebar |
ø8 B500C |
|
Bar spacing |
300 |
|
Reinforcing zone length |
600 |
|
Top and bottom rebar dimensions |
100 |
To see the connection of B-9 and B-11 beams:
To reinforce the B-4 beams, we will use ready-made reinforcing cages.
To create a cage that will be used for reinforcement, do the following:
Manage styles – Reinforcement –
Reinforcement units.
button.|
Mark |
C-1 |
|
Type of cage |
Volume |
|
Reinforcement method |
Welded |
|
Length |
4750 |
|
Width |
336 |
|
Height |
338 |
|
Corner rebar |
ø20 A400 |
|
Rebar |
ø16 A400 |
|
Enable reinforcing bars |
On |
|
Rebar for reinforcing |
ø16 A400 |
|
Number of rebars (width) |
3 |
|
Number of rebars (depth) |
3 |
|
Left end overhang length |
25 |
|
Right end overhang length |
25 |
|
Rebar |
ø10 A400 |
|
Bar spacing |
300 |
|
Reinforcing zone length |
1200 |
|
Top and bottom rebar dimensions |
100 |
Create and assign the Reinforcement B-4:
|
Cover |
25 |
|
Reinforcement method |
Place a reinforcing cages |
|
Reinforcing cage |
Cage C-1 |
Switch back to the Monochrome visual style. To create a wall reinforcement, let's copy an object from another project.
(Ctrl+C).
(Ctrl+V) and then press Esc.
Manage styles – Reinforcement –
Reinforcement style.Let's set the reinforcement for W-1 and W-3:
Clear cover | |
|---|---|
Inner | 20,00 |
Outer | 20,00 |
Left | 20,00 |
Right | 20,00 |
Top | 20,00 |
Bottom | 20,00 |
For openings (windows and doors) | 25,00 |
Longitudinal rebar | |
Rebar style | ø20 A400 |
Step | 400,00 |
Transverse rebar | |
Rebar style | ø20 A400 |
Step | 400,00 |
Overhangs | |
Use hook | No |
Top overhang 1 | 300,00 |
Top overhang 2 | 300,00 |
Start overhang | 300,00 |
C-shaped fixator | |
Rebar style | ø8 A400 |
Leg length | 15,00 |
Horizontal step | 2 |
Vertical step | 2 |
Use chess order | No |
U-shaped rebar | |
Edge reinforcement | Yes |
Rebar style | ø8 A400 |
Leg length | 400,00 |
Base length | 100,00 |
Step | 300 |
To see how the reinforced walls looks select the Wireframe Visual style. If there are overhangs at the ends of the walls, select the walls with incorrect reinforcement and then select the Flip command from the context menu.
For the remaining carrying walls, select or create suitable reinforcement styles.
To reinforce the floor of the 1st floor, we will create a reinforcement style, Double mesh with U-shaped edge reinforcement. To set the reinforcement style:
General | |
Use edge reinforcement | Yes |
Use mesh supports | Yes |
Clear cover | |
Top face | 25 |
Bottom face | 25 |
Side faces | 50 |
Longitudinal rebar | |
Longitudinal rebar style | ø20 A400 |
Step | 400 |
Transverse rebar | |
Transverse rebar style | ø20 A400 |
Step | 400 |
Edge reinforcement | |
Edge rebar style | ø10 A400 |
Left leg length | 200 |
Right leg length | 200 |
Edge rebar step | 300 |
Bending factor | 3 |
Mesh supports | |
Supports rebar style | ø8 A400 |
Base length | 300 |
Leg length | 100 |
Vertical step | 600 |
Horizontal step | 600 |
Use chess order | Yes |
To reinforce the other floors, create a Floor reinforcement reinforcement style based on the Floor reinforcement template:
|
Cover |
50 |
|
Reinforcement method |
Parametric meshes |
|
Overhangs |
No |
|
End Overhang length |
50 |
|
Structure |
Without alternating reinforcement |
|
Cover |
30 |
|
Longitudinal rebar |
ø20 A400 |
|
Longitudinal rebars spacing |
400 |
|
Transverse rebar |
ø20 A400 |
|
Transverse rebars spacing |
400 |
Assign the Floor reinforcement style to others floors.
To strengthen openings in the floors you need to create a style of reinforcement for openings:
|
Cover |
40 |
|
Reinforcement method |
Parametric welded |
|
Overhangs length |
400 |
|
Structure |
All objects |
|
Rebar |
ø20 A400 |
|
Rebar location |
50 |
|
Bar spacing |
200 |
|
Rebar |
ø8 B500C |
|
Bar spacing |
300 |
Assign the created reinforcement style to stair openings using Monochrome visual style.
To see how the reinforced openings looks select the Wireframe Visual style.